ULP-2521
Product Features
It is widely used for automatic water dispenser in residential area and school, direct drinking equipment in office, pure water machine in medical laboratory,small-sized desalination device etc.
TU14
TU15
TU16
TU23
TU31
TU32
Sheet Type




TU14
TU15
TU16
TU23
TU31
TU32
SPECIFICATIONS & PARAMETERS
Model | Stable Rejection | Min Rejection | Permeate Flow | Effective Membrane Area |
(%) | (%) | GPD(m³/d) | ft2(m2) | |
ULP-2521 | 99.3 | 99.0 | 350(1.32) | 14(1.3) |
Testing Conditions | Operating pressure | 150psi( 1.03MPa) | ||
Test solution temperature | 25 ℃ | |||
Test solution concentration (NaCl) | 1500ppm | |||
PH value | 7-8 | |||
Recovery rate of single membrane element | 8% | |||
Flow range of single membrane element | ±15% | |||
Operating Conditions & Limitis | Maximum operating pressure | 600 psi(4.14MPa) | ||
Maximum temperature | 45 ℃ | |||
Maximum feedwater fow | Maximum feedwater fow:6gpm(1.4 m3/h) | |||
Maximum feedwater flow SDI15 | 5 | |||
Maximum concentration of free chlorine: | <0.1ppm | |||
Allowed pH range for chemical cleaning | 3-10 | |||
Allowed pH range for feedwater in operation | 2-11 | |||
Maximum pressure drop per element | 15psi(0.1MPa) |